&1. Structural introduction of vertical gas-fired steam boiler: &Vertical gas-fired steam boiler is a vertical internal combustion fire tube boiler. The high-temperature flue gas generated by the combustion of the burner sequentially washes the furnace liner and the threaded smoke pipe with the spiral spoiler inserted from the top, and then is discharged from the lower smoke chamber through the chimney into the atmosphere. The boiler is equipped with an industrial burner with good technical performance. It adopts advanced technologies such as automatic combustion ratio adjustment, automatic water supply adjustment, program start and stop, and fully automatic operation. It also has high and low water level alarms, extremely low water level, ultra-high steam pressure, flameout and other automatic Protective function. This type of boiler has the characteristics of compact structure, safety and reliability, easy operation, rapid installation, less pollution, low noise and high efficiency.
2. Description of the vertical gas steam boiler control system:
The vertical gas steam boiler uses a fully automatic burner with good technical performance as the main combustion equipment. The combustion program of the burner is controlled by a more advanced Combustion program controller control can realize various functions necessary for normal combustion of the boiler. It can automatically implement protective shutdown in normal conditions, accident conditions and extraordinary circumstances. It is equipped with corresponding water level controllers and pressure regulators to achieve High and low water level indication, overpressure indication, and adjustment ensure that the water level fluctuates within the normal range and the steam pressure is within the allowable pressure fluctuation range. Protective stop indication is achieved when the water level is extremely low or overpressure.
3. Installation of vertical gas-fired steam boiler host: Kuitun small gas-fired heating boiler
&⑴. The determination of the boiler foundation should be based on the local soil quality, and it will be redesigned by the civil engineering department with reference to the boiler foundation diagram provided.
&⑵ After the boiler foundation reaches strength, inspection and acceptance should be carried out according to the boiler drawings, and three baselines for the entire boiler should be drawn:
, transverse baseline & drum center. Kuitun small gas heating boiler
Longitudinal reference line & base position line.
Kuitun small gas heating boiler